揭陽電梯安全回路: (總) ROS-80
上部安全: 61A-70
下部安全: 70-80
急仃開關: ROS-61
印板: 61-61A
56-57: (TOP) STOP < 急停按鈕 >
57-59: (BOT) REST RUN < 停止開關 >;
59-59A: (BOT) STOP < 急停按鈕 >;
59A-59B: (BOT) DOS < 前沿板開關 >;
62-62A: (TOP-R) E-STOP < 蜂鳴器 停止鑰匙開關 >;
62A-62B: (TOP-R) HGS < 扶手入口保護裝置 >;
62B-62D: (TOP-R) SRS < 梯級滾輪開關 >;
62D-63 : (TOP-R) HBS < 扶手帶斷帶保護開關 >;
63-63A: (TOP-L) E-STOP < 急停按鈕 >;
63A-63C: (TOP-L) HGS < 扶手帶入口保護裝置 >;
63C-63D: (TOP-L) SRS < 梯級滾輪開關 >;
63D-63E: (TOP-L) CRS < 彎曲部導軌安全開關 >;
63E-64: (TOP-L) HBS < 扶手帶斷帶保護開關 >;
64-65: (TOP) HGD < 高速限速開關 >;
65-66: (TOP) DCS < 驅動鏈安全開關 >;
75-75A: (BOT-R) E-STOP < 停止鑰匙開關 >;
75A-75B: (BOT-R) HGS < 扶手入口保護裝置 >;
75B-75C: (BOT-R) SCS < 梯級鏈安全開關 >;
75C-76: (BOT-R) SRS < 梯級滾輪開關 >;
76-76A: (BOT-L) E-STOP < 急停按鈕 >;
76A-76B: (BOT-L) HGS < 扶手入口保護開關 >;
76B-76C: (BOT-L) SCS < 梯級鏈安全開關 >;
76C-76D: (BOT-L) CRS < 彎曲部導軌開關 >;
76D-77: (BOT-L) SRS < 梯級滾輪開關 >;
77-77A: (BOT-R) CSS < 梳齒板開關 >;
77A-77B: (BOT-R) SSS < 圍裙板開關 >;
77B-79: (BOT-L) SSS < 圍裙板開關 >;
79-79A: (TOP-R) SSS < 圍裙板開關 >;
79A-79B: (TOP-L) SSS < 圍裙板開關 >;
79B-79C: (TOP-L) CSS < 梳齒板安全開關 >。
揭陽電梯控制器(ESCCNT)設定要領
1.切斷控制屏電源,向設定開關(JP1)插入跨接用插頭
2.將控制屏上的鈕子開關由“REST”側板向“SIOP”側,如果不作這個操作,在控制器設定終了的同時,自動扶梯可能進入運轉狀態,特別危險。
3.在控制屏內合上開關“ACB”
4.將設定選擇旋轉開關配合設定項目編號,旋轉開關“SEL”的開關位置編號與設定項目的對應參照控制器設定表。通過撳按鈕開關“UP”或者“DOWN”,使顯示器所表示的值與要求的設定值一致。
撳“SET”寫入開關,將設定值寫入RAM。
但是,如果不撳“SET”開關,經過30秒以后又回到原來的設定值,控制器繼續整定時將會重復直至現在的操作。
設定終了以后,將旋轉開關“SEL”回到“0”的位置,通過這次操作,控制器的設定完成了。
控制器的設定如果是標準的,改變設定沒有必要。
5.將設定開關(JP1)的跨接用插頭拔出來。
6.將控制屏的開關“ACB”關斷。將控制屏上的鈕子開關從“STOP”側板向“REST”側。